ORP Sensors & Transmitters

Products for effective ORP measurement in all industries.

1 - 48 of 51 Products
Multiparameter Handheld Liquiline Mobile CML18
Endress+Hauser
Liquiline Mobile CML18_s_stehend_001.png
Lean Lean
Request Information
Combined pH/ORP Sensor Memosens CPS76E
Endress+Hauser
CPS76E-combined-pH-ORP-sensor.png
Extended Extended
Request Information
Manual or Automatic Retractable Assembly Cleanfit CPA474
Endress+Hauser
CPA474.png
Request Information
Digital ORP Sensor Memosens CPS62E
Endress+Hauser
CPS62E-ORP-sensor-EX.png
Extended Extended
Request Information
Manual or Automatic Retractable Assembly Cleanfit CPA875
Endress+Hauser
CPA875_pneumatic_measuring_position.png
Request Information
Digital ORP Sensor Ceragel CPS72D
Endress+Hauser
CPS72D-G-7PT21.png
Request Information
pH Buffer CPY20
Endress+Hauser
CPY20 pH buffers.png
Request Information
Process Assembly Ecofit CPA640
Endress+Hauser
CPA640.png
Request Information
Liquiline Edge Module CYY7
Endress+Hauser
Liquiline Edge Module CYY7
Extended Extended
Request Information
4-Channel Transmitter Liquiline CM444
Endress+Hauser
CM44_pH.png
Extended Extended
Request Information
Flow Assembly for Multi-Parameter Measurements Flowfit CYA27
Endress+Hauser
Flow assembly for multi-parameter measurements Flowfit CYA27
Request Information
1-Channel Transmitter Liquiline Compact CM82
Endress+Hauser
Liquiline Compact CM82_angular.png
Request Information
Analog ORP Sensor Orbipac CPF82
Endress+Hauser
cpf82_analog_ORP_sensor_angular.png
Request Information
Flow Assembly Flowfit CYA21
Endress+Hauser
CYA21_Durchflussarmatur 71042404_g_001.png
Request Information
Digital ORP Sensor Memosens CPS42E
Endress+Hauser
CPS42E-ORP-sensor-Ex.png
Request Information
Digital ORP Sensor Ceraliquid CPS42D
Endress+Hauser
CPS42D_digital_ORP_sensor.png
Request Information
Manual or Automatic Retractable Assembly Cleanfit CPA871
Endress+Hauser
cpa871_peek_immersion_chamber_manual.png
Request Information
4-Channel Transmitter Liquiline CM444R
Endress+Hauser
CM444R.png
Extended Extended
Request Information
1-/2-Channel Transmitter Liquiline CM442
Endress+Hauser
CM44_pH.png
Extended Extended
Request Information
Manual Retractable Assembly Cleanfit CPA450
Endress+Hauser
CPA450.png
Request Information
Immersion Assembly Dipfit CPA111
Endress+Hauser
CPA111_front.png
Request Information
Analog ORP Sensor Ceragel CPS72
Endress+Hauser
CPS72_Top68.png
Request Information
Digital ORP Sensor Memosens CPS92E
Endress+Hauser
CPS92E-ORP-sensor_EX.png
Extended Extended
Request Information
1-Channel Transmitter Liquiline M CM42
Endress+Hauser
CM42_plastic version_angular.png
Extended Extended
Request Information
1-/2-Channel Transmitter Liquiline CM442R
Endress+Hauser
CM442R.png
Extended Extended
Request Information
Digital ORP Sensor Orbisint CPS12D
Endress+Hauser
cps12d - Memosens - nicht Ex.png
Request Information
pH/ORP Transmitter Liquisys CPM223
Endress+Hauser
CPM223.png
Request Information
Flow Assembly Flowfit CPA25
Endress+Hauser
Flow assembly Flowfit CPA25
Lean Lean
Request Information
pH/ORP Transmitter Liquisys CPM253
Endress+Hauser
CPM253.png
Request Information
Multichannel Transmitter Liquiline CM44P
Endress+Hauser
Liquiline_CM44P_AU.png
Extended Extended
Request Information
Digital ORP Sensor Orbipore CPS92D
Endress+Hauser
CPS92D-7PB21 - 001.png
Request Information
Immersion Assembly Dipfit CPA140
Endress+Hauser
CPA140_front.png
Request Information
Flow Assembly CYA680
Endress+Hauser
Flow assembly CYA680
Request Information
Immersion Assembly Flexdip CYA112
Endress+Hauser
CYA112_Rendering_2.png
Request Information
Digital ORP Sensor Memosens CPF82E
Endress+Hauser
CPF82E-digital-ORP-sensor.png
Extended Extended
Request Information
Manual or Automatic Retractable Assembly Cleanfit CPA473
Endress+Hauser
CPA473_front.png
Request Information
Digital ORP Sensor Memosens CPS72E
Endress+Hauser
CPS72E-ORP-sensor.png
Extended Extended
Request Information
Digital Combined pH/ORP Sensor Memosens CPS16E
Endress+Hauser
CPS16E-combined-pH_ORP-sensor.png
Extended Extended
Request Information
8-Channel Transmitter Liquiline CM448
Endress+Hauser
CM44_pH.png
Extended Extended
Request Information
Modular Holder System Flexdip CYH112
Endress+Hauser
CYA112_Rendering_2.png
Request Information
Digital Combined pH/ORP Sensor Memosens CPS96E
Endress+Hauser
CPS96E-combined-pH-ORP-sensor-Beauty.png
Extended Extended
Request Information
Process Assembly Unifit CPA842
Endress+Hauser
CPA842_front_with cable protection.png
Request Information
8-Channel Transmitter Liquiline CM448R
Endress+Hauser
CM448R.png
Extended Extended
Request Information
Analog ORP Sensor Orbisint CPS12
Endress+Hauser
cps12 - top68.png
Request Information
Cleaning and Calibration System Liquiline Control CDC90
Endress+Hauser
CDC90_front.png
Request Information
Manual or Automatic Retractable Assembly Cleanfit CPA472D
Endress+Hauser
CPA472D_front.png
Request Information
1-Channel Transmitter Liquiline CM14
Endress+Hauser
cm14_12_04_2011_007_pH.png
Fundamental Fundamental
Request Information
Digital ORP Sensor Orbipac CPF82D
Endress+Hauser
CPF82D-ORP-sensor-angular.png
Request Information

ORP Sensors & Transmitters

ORP (oxidation-reduction potential) sensors and transmitters provide a real-time electrochemical indicator of the oxidizing or reducing character of an aqueous process. ORP is often used as a trend signal for disinfection capability, aeration control in wastewater, detoxification steps in electroplating, and redox-driven treatment processes such as flue gas scrubbing. The measurement is especially valuable where a stable redox environment is required for consistent reaction outcomes.

ORP measurement is performed using a precious metal measuring electrode (commonly silver, gold, or platinum) paired with a stable reference system such as Ag/AgCl. The measured potential reflects electron activity in the medium, and the ORP value is calculated from the potential difference between the measuring and reference systems using the Nernst equation, typically expressed in mV. Because ORP represents the combined effect of multiple redox pairs, it is a sum parameter and does not identify individual substances or concentrations.

Selection is application-driven. Gold electrodes are positioned for oxidation processes (for example cyanide oxidation or ozone measurement), while platinum electrodes are positioned for reducing processes (such as chromate reduction or chlorine dosing). Matching diaphragm and reference design to fouling risk, chemical compatibility, and stability requirements is central to achieving durable, low-drift operation. Temperature reporting is also important because redox potential is temperature dependent and must be stated to compare measurements.

Benefits include actionable trend information for control decisions and a portfolio that scales from basic measurement to broader multiparameter strategies. The offering includes pH/ORP combination sensors that provide both pH and ORP values for a more detailed picture and can support rH determination. Calibration and adjustment are supported through ORP buffers, solutions, and standards designed to maintain confidence in the electrochemical loop over time.

Typical applications span drinking water and pool disinfection monitoring, wastewater treatment control, and industrial oxidation/reduction processes where redox balance is tied to product quality or environmental performance. Integration with suitable transmitters and assemblies enables stable installation in open basins, pipelines, or sampling loops, and supports consistent measurement in hygienic or hazardous-area conditions where required.

At Eastern Controls, We are proud to be the exclusive authorized sales and service representative for Endress+Hauser.