ORP Sensors & Transmitters

Products for effective ORP measurement in all industries.

1 - 48 of 51 Products
Liquiline, 4-wire CM448
Endress+Hauser
Liquiline, 4-wire CM448
Extended Extended
Request Information
Dipfit CPA111
Endress+Hauser
Dipfit CPA111
Request Information
Transmitter Liquiline, 4-wire CM442
Endress+Hauser
Transmitter Liquiline, 4-wire CM442
Extended Extended
Request Information
Flowfit CPA25
Endress+Hauser
Flowfit CPA25
Lean Lean
Request Information
Memosens CPS16E
Endress+Hauser
Memosens CPS16E
Extended Extended
Request Information
Liquiline, 4-wire CM444
Endress+Hauser
Liquiline, 4-wire CM444
Extended Extended
Request Information
pH/ORP sensor Memosens CPS96E
Endress+Hauser
pH/ORP sensor Memosens CPS96E
Extended Extended
Request Information
Flowfit CYA21
Endress+Hauser
Flowfit CYA21
Request Information
In-line Photometer CYA680
Endress+Hauser
In-line Photometer CYA680
Request Information
Liquiline, 4-wire CM442R
Endress+Hauser
Liquiline, 4-wire CM442R
Extended Extended
Request Information
Liquiline, 4-wire CM44P
Endress+Hauser
Liquiline, 4-wire CM44P
Extended Extended
Request Information
Ceraliquid CPS42D
Endress+Hauser
Ceraliquid CPS42D
Request Information
Memosens CPS76E
Endress+Hauser
Memosens CPS76E
Extended Extended
Request Information
Memosens CPS42E
Endress+Hauser
Memosens CPS42E
Request Information
Orbipac CPF82D
Endress+Hauser
Orbipac CPF82D
Request Information
Orbipac CPF82
Endress+Hauser
Orbipac CPF82
Request Information
Flowfit CPA240
Endress+Hauser
Flowfit CPA240
Request Information
pH buffer Buffer solution CPY20
Endress+Hauser
pH buffer Buffer solution CPY20
Request Information
Flowfit CYA27
Endress+Hauser
Flowfit CYA27
Request Information
Transmitter Liquiline, 4-wire CM14
Endress+Hauser
Transmitter Liquiline, 4-wire CM14
Fundamental Fundamental
Request Information
Transmitter Liquiline, 2-wire CM42
Endress+Hauser
Transmitter Liquiline, 2-wire CM42
Extended Extended
Request Information
Liquiline, 4-wire CM448R
Endress+Hauser
Liquiline, 4-wire CM448R
Extended Extended
Request Information
Liquisys CPM253
Endress+Hauser
Liquisys CPM253
Request Information
Liquiline, 4-wire CM444R
Endress+Hauser
Liquiline, 4-wire CM444R
Extended Extended
Request Information
Liquiline, 4-wire CYY7
Endress+Hauser
Liquiline, 4-wire CYY7
Extended Extended
Request Information
Memosens CPS62E
Endress+Hauser
Memosens CPS62E
Extended Extended
Request Information
Cleanfit CPA871
Endress+Hauser
Cleanfit CPA871
Request Information
Flexdip CYH112
Endress+Hauser
Flexdip CYH112
Request Information
Ceragel CPS72
Endress+Hauser
Ceragel CPS72
Request Information
Ceragel CPS72D
Endress+Hauser
Ceragel CPS72D
Request Information
Transmitter Liquiline, 2-wire CM82
Endress+Hauser
Transmitter Liquiline, 2-wire CM82
Request Information
Orbisint CPS12D
Endress+Hauser
Orbisint CPS12D
Request Information
Cleanfit CPA875
Endress+Hauser
Cleanfit CPA875
Request Information
Memosens CPF82E
Endress+Hauser
Memosens CPF82E
Extended Extended
Request Information
Memosens CPS92E
Endress+Hauser
Memosens CPS92E
Extended Extended
Request Information
Flexdip CYA112
Endress+Hauser
Flexdip CYA112
Request Information
Memosens CPS72E
Endress+Hauser
Memosens CPS72E
Extended Extended
Request Information
Cleanfit CPA472D
Endress+Hauser
Cleanfit CPA472D
Request Information
Liquisys CPM223
Endress+Hauser
Liquisys CPM223
Request Information
Cleanfit CPA473
Endress+Hauser
Cleanfit CPA473
Request Information
Multi parameter measuring device Hand held CML18
Endress+Hauser
Multi parameter measuring device Hand held CML18
Lean Lean
Request Information
Unifit CPA842
Endress+Hauser
Unifit CPA842
Request Information
Ecofit CPA640
Endress+Hauser
Ecofit CPA640
Request Information
Liquiline Control CDC90
Endress+Hauser
Liquiline Control CDC90
Request Information
Redox sensor Memosens CPS12E
Endress+Hauser
Redox sensor Memosens CPS12E
Extended Extended
Request Information
Dipfit CPA140
Endress+Hauser
Dipfit CPA140
Request Information
Cleanfit CPA474
Endress+Hauser
Cleanfit CPA474
Request Information
Orbipore CPS92D
Endress+Hauser
Orbipore CPS92D
Request Information

ORP Sensors & Transmitters

ORP (oxidation-reduction potential) sensors and transmitters provide a real-time electrochemical indicator of the oxidizing or reducing character of an aqueous process. ORP is often used as a trend signal for disinfection capability, aeration control in wastewater, detoxification steps in electroplating, and redox-driven treatment processes such as flue gas scrubbing. The measurement is especially valuable where a stable redox environment is required for consistent reaction outcomes.

ORP measurement is performed using a precious metal measuring electrode (commonly silver, gold, or platinum) paired with a stable reference system such as Ag/AgCl. The measured potential reflects electron activity in the medium, and the ORP value is calculated from the potential difference between the measuring and reference systems using the Nernst equation, typically expressed in mV. Because ORP represents the combined effect of multiple redox pairs, it is a sum parameter and does not identify individual substances or concentrations.

Selection is application-driven. Gold electrodes are positioned for oxidation processes (for example cyanide oxidation or ozone measurement), while platinum electrodes are positioned for reducing processes (such as chromate reduction or chlorine dosing). Matching diaphragm and reference design to fouling risk, chemical compatibility, and stability requirements is central to achieving durable, low-drift operation. Temperature reporting is also important because redox potential is temperature dependent and must be stated to compare measurements.

Benefits include actionable trend information for control decisions and a portfolio that scales from basic measurement to broader multiparameter strategies. The offering includes pH/ORP combination sensors that provide both pH and ORP values for a more detailed picture and can support rH determination. Calibration and adjustment are supported through ORP buffers, solutions, and standards designed to maintain confidence in the electrochemical loop over time.

Typical applications span drinking water and pool disinfection monitoring, wastewater treatment control, and industrial oxidation/reduction processes where redox balance is tied to product quality or environmental performance. Integration with suitable transmitters and assemblies enables stable installation in open basins, pipelines, or sampling loops, and supports consistent measurement in hygienic or hazardous-area conditions where required.

At Eastern Controls, We are proud to be the exclusive authorized sales and service representative for Endress+Hauser.