FLOWSIC IFL500

Brand: Endress+Hauser

FLOWSIC IFL500

Brand: Endress+Hauser

Eastern Controls, Endress+Hauser's exclusive USA representative in:
● DE ● MD ● NJ ●  Metro NY ● Eastern PA 

Xpert Xpert

Specs at a Glance

Measured variables:
Volume a. c., volumetric flow a. c., gas velocity, volume s. c. (*), volume flow under s.c. (*)
(*) additional function included with integrated volume correction
Nominal pipe size:
DN 50 (2") … DN 150 (6")
Measuring Medium:
Natural gas (dry, odorized)

Field of application

The FLOWSIC500 ultrasonic flowmeter enables extremely accurate natural gas distribution measurement. It is overload-proof, accurate and is monitored by an intelligent diagnostics system. It can easily be integrated into existing measuring stations. It operates either in a self-sufficient energy configuration or in failsafe network operation with battery back-up. It complies with all pertinent standards and directives and provides the security of a continuous and blockage-free gas supply.

Natural gas distribution in transfer and measuring stations for municipal and regional gas suppliers

Measuring stations in industrial and commercial application

Key Benefits

  • Highest measurement certainty and safety of continuous gas supply
  • Reduction of installation costs due to integrated flow conversion
  • Simple installation, compatible with conventional technologies (turbine and rotary displacement meters)
  • Minimal operating costs due to being nearly maintenance-free
  • Simplified recalibration due to straightforward cartridge exchange
  • Reliable under dynamic load changes
  • Self-sufficient operation

Specifications

Industry

  • Power & Energy
  • Oil & Gas

Product Family

  • FLOWSIC

Gas

Measured variables

  • Volume a. c., volumetric flow a. c., gas velocity, volume s. c. (*), volume flow under s.c. (*)
  • (*) additional function included with integrated volume correction

Measuring Medium

  • Natural gas (dry, odorized)

Repeatability

  • ≤ 0.1 %

Accuracy

  • Qmin up to 0.1 Qmax ≤ ± 1 %
  • 0.1 Qmax up to Qmax ≤ ± 0.5 %
  • Accuracy class 1; maximum allowed error limits
  • Qmin up to 0.1 Qmax ≤ ± 2 %
  • 0.1 Qmax up to Qmax ≤ ± 1 %
  • After high pressure flow calibration: ±0.2 % at test pressure; otherwise ±0.5 %

Medium temperature range

  • -25 °C ... +60 °C
  • Optional: –40 °C ... +70 °C
  • (–13 °F ... +140 °F
  • Optional: –40 °F ... +158 °F)

Operating pressure range

  • PN16 (EN 1092-1): 0 bar (g) ... 16 bar (g) / 0 psi(g) ... 232 psi(g)
  • Class 150 (ASME B16.5): 0 bar (g) ... 20 bar (g) / 0 psi(g) ... 290 psi(g)

Nominal pipe size

  • DN 50 (2") … DN 150 (6")

Metrological approvals and certificates

  • MID: 2014/32/EU
  • OIML R 137-1&2:2012
  • EN 12405: 2010 (for integrated flow conversion)

Hazardous area approvals

  • IECEx
  • Ex ia [ia] IIC T4 Gb, Ex op is IIC T4 Gb
  • ATEX
  • II 2G Ex ia [ia] IIC T4 Gb, II 2G Ex op is IIC T4 Gb
  • NEC/CEC (US/CA)
  • CSA: I.S. for Class 1 Division 1 Groups C and D T4; Ex/AEx ia IIB T4 Ga

Digital Outputs

  • Configurations:
  • LF pulses + malfunction, electrically isolated (fmax = 100 Hz)
  • HF pulses + malfunction, electrically isolated (fmax = 2 kHz)
  • Encoder + LF pulses, electrically isolated (fmax = 100 Hz)
  • Encoder + HF pulses, not electrically isolated (fmax = 2 kHz)
  • 2x pulses, HF and LF, electrically isolated (fmax = 2 kHz / 100 Hz)

Digital communication

  • R-S485 (external powered, in combination with LF- or HF pulses)

Documentation

show more