FLOWSIC IFL900
Brand: Endress+HauserFLOWSIC IFL900
Brand: Endress+Hauser
Xpert Specs at a Glance
Nominal pipe size:
8 ″ ... 36 ″
DN200 ... DN900, Schedule 40S/STD acc. ASME B36.19 / B36.10, others on request
DN200 ... DN900, Schedule 40S/STD acc. ASME B36.19 / B36.10, others on request
Measuring Medium:
LNG (Liquefied Natural Gas)
Measured variables:
Volume a. c., volumetric flow a. c., Fluid velocity, Speed of sound
Field of application
FLOWSIC900 is the input of our many years of experience in natural gas measurement: a flowmeter specially tailored to the requirements of the LNG industry. It offers the required custody transfer accuracy for volume flow measurement and meets highest metrological standards. With FLOWSIC900 and the proven products FLOWSIC600-XT and FLOWSIC100 Flare-XT, we offer high-end measurement solutions from a single source to bring measurement performance and reliability in LNG plants to a new level.
Custody transfer measurement of LNG
On- and offshore applications
Liquefaction, transport and storage of LNG
Key Benefits
- Low measurement uncertainty directly at custody transfer point reducing financial risks during LNG-transaction
- Increased transparency during LNG transaction by dynamic & real-time measurement & diagnostics
- Operational expenditure savings by reduced boil-off gas losses and efficient LNG transfer due to minimized pressure drop
- Capital expenditure savings by simpliefied meter integration and installation due to compact design and factory pre-insulation
- Easy and fast access during commissioning and regular checks with remote SPU
Specifications
Brand
Industry
- Oil & Gas
Product Family
- FLOWSIC
Liquified Natural Gas (LNG)
Measured variables
- Volume a. c., volumetric flow a. c., Fluid velocity, Speed of sound
Measuring Medium
- LNG (Liquefied Natural Gas)
Repeatability
- ≤ ± 0.05 % of the measured value
Accuracy
- Typical error limits Qmin ... Qmax
- ≤ ±0.2 % of reading
- After flow calibration and adjustment
Operating pressure range
- 0 bar (g) ... 19 bar (g) / 0 psi(g) … 275 psi(g)
Nominal pipe size
- 8 ″ ... 36 ″
- DN200 ... DN900, Schedule 40S/STD acc. ASME B36.19 / B36.10, others on request
Metrological approvals and certificates
- Metrological:
- OIML R117 Class 0.3
- Explosion protection:
- IECEx: IEC 60079
- cCSA: CAN/CSA C22.2 No. 60079
- CSAus: UL 60079, UL 61010, UL 1203, FM3600
- Pressure rating:
- ASME: B16.5/B16.47, B36.19/B36.10
- Other: API MPMS Ch. 5.8
- For details see operating instructions
Hazardous area approvals
- IECEx
- Ex db ia [ia Ga] IIA T4 Gb
- NEC/CEC (US/CA)
- Class I, Division 2, Group D T4
- Class I, Zone 1, AEx db ia [ia Ga] IIA T4 Gb
- Class I, Division 1, Group D T4
Digital Outputs
- 2 Digital output/Frequency output:
- Others on request
Digital communication
- Modbus RS-485 (2x)
- Modbus RTU/ASCII
- Blutooth
- USB