Specs at a Glance

Measured variables:
Volumetric flow a. c., volume a. c., gas velocity, sound velocity
Nominal pipe size:
2" / 3" / 4"
Measuring Medium:
Natural gas, Associated gas , Raw Natural gas

Field of application

FLOWSIC600 DRU-S is a compact and innovative ultrasonic gas flowmeter for gas production. The gas meter is specifically designed for wellhead and gaslift applications. With a measuring range of more than 1:100, the FLOWSIC600 DRU-S covers flow ranges that previously required several orifice plates. Its special "wet gas robust" design ensures continuous measurement even under continuous high liquid loads. FLOWSIC600 DRU-S allows remote monitoring of measurement and diagnostic data.

Natural gas measurement in gas production

Associated gas measurement in oil production

Wellhead and gaslift measurement

Raw natural gas measurement at gas treatment plants (VRU, VRT, dehydration units, etc.)

Key Benefits

  • Highly reliable – continuous gas measurement even in wet and dirty process conditions
  • Low initial investment - accurate measurement without expensive flow calibration
  • Elimination of scheduled maintenance with real-time remote diagnostics
  • Advanced process monitoring capability with unique liquid detection
  • Long life - wet gas resistant titanium ultrasonic sensors

Specifications

Industry

  • Power & Energy
  • Oil & Gas

Product Family

  • FLOWSIC

Gas

Measured variables

  • Volumetric flow a. c., volume a. c., gas velocity, sound velocity

Measuring Medium

  • Natural gas, Associated gas , Raw Natural gas

Repeatability

  • ± 0.2 % of the measured value
  • (between Qt and Qmax depending on the installation requirements)

Accuracy

  • Error limits Qt ... Qmax ± 2 %

Medium temperature range

  • –40 °C ... +100 °C / –40 °F … 212 °F

Operating pressure range

  • 0 bar(g) … 16 bar(g) / 0 psi(g) … 230 psi(g) for ANSI CL150
  • 0 bar(g) … 100 bar(g) / 0 psi(g) … 1450 psi(g) for ANSI CL600

Nominal pipe size

  • 2" / 3" / 4"

Hazardous area approvals

  • IECEx:
  • Gb/Ga Ex db eb ib [ia Ga] IIA T4
  • Ultrasonic transducer, intrinsically safe
  • ATEX:
  • II 1/2 (1) G Ex ia/ db eb ia [ia Ga] IIA T4 …T1 Ga/Gb
  • NEC/CEC (US/CA):
  • Class I, Division 1, Group D T4
  • Class I, Division 2, Group D T4
  • Ultrasonic transducers intrinsically safe

Digital Outputs

  • 2 DO and 1 FO:
  • 30 V, 10 mA
  • Passive, galvanically isolated, open collector, fmax = 6 kHz (scalable)

Digital communication

  • RTU RS-485 (2x, for configuration, data output and diagnostics)
  • ASCII RS-485 (2x, for configuration, data output and diagnostics)

Documentation