FLOWSIC IFL300
Brand: Endress+HauserFLOWSIC IFL300
Brand: Endress+Hauser
Xpert Specs at a Glance
Measuring range:
Gas velocity 0.3 ... 60 m/s
Depending on the nominal size of the pipe
Depending on the nominal size of the pipe
Measured variables:
Volumetric flow a. c., volume a. c., gas velocity, sound velocity
Field of application
The FLOWSIC300 ultrasonic flowmeter features a unique combination of high quality components, large measuring range, simple installation, and low installation costs. It can be used anywhere where custody approval is not required: For internal measurements in the natural gas grid and with process measurements in the petrochemical industry. FLOWSIC300 incorporates proven technology and components of the rugged custody transfer quality gas flowmeters for custody transfer.
Gas flow measurement in non custody transfer applications
Control measurements in the field of natural gas transfer and storage
Internal measurements for balancing purposes
Key Benefits
- Simple installation into existing pipelines
- Efficient solution, especially for pipe diameters over 12 inches, thanks to installation onto existing pipelines and without need for a meter body
- Reduced acquisition costs – the sensor extraction tool can be used for multiple devices
- Low maintenance, wear and no deterioration
- Low operating costs thanks to automated diagnostics and condition-based maintenance
- Suitable for installation in underground compartments via remote electronics and sensors with enclosure rating IP 68
Specifications
Brand
Industry
- Power & Energy
- Oil & Gas
Product Family
- FLOWSIC
Gas
Measured variables
- Volumetric flow a. c., volume a. c., gas velocity, sound velocity
Measuring range
- Gas velocity 0.3 ... 60 m/s
- Depending on the nominal size of the pipe
Max. Measurment error
- Max. 1:130
Medium temperature range
- –40 °C ... +180 °C
Operating pressure range
- 10 bar (g) ... 100 bar (g)
Nominal pipe size
- 4 ″ ... 56 ″
Hazardous area approvals
- ATEX: II 1/2G Ex de iB [ia] IIC Ta
- The ultrasonic transducers are intrinsically safe: "ia"
Outputs
- 3 outputs:
- Passive, electrically isolated, Open Collector or according to NAMUR (EN 50227), fmax = 6 kHz (scalable)
Digital Outputs
- 5 relay outputs (change-over contacts), potential-free:
- - 48 V AC, 1 A
- Safety extra-low voltage; for status signals "operation/malfunction", "limit value", "warning", "maintenance" and "check cycle"
Digital communication
- ASCII RS-485
- RTU RS-485