FLOWSIC IFL200
Brand: Endress+HauserFLOWSIC IFL200
Brand: Endress+Hauser
Xpert Specs at a Glance
Measured variables:
Flow velocity, Direction of flow, temperature
Conformities:
RABT 2006
ASTRA "Guideline - Ventilation of Road Tunnels" (2008)
RVS 09.02.22
ASTRA "Guideline - Ventilation of Road Tunnels" (2008)
RVS 09.02.22
Measuring range:
Flow Velocity: 0 ... ± 20 m/s
Field of application
The FLOWSIC200 is used for the contact-free and accurate measurement of flow velocity and flow direction inside tunnels or exhaust ventilation ducts. Ultrasonic technology provides the cross-sectional mean average value of the flow velocity. This device is used for measurement necessary for optimal ventilation control and reducing running costs to a minimum when air flow is dictated by climatic conditions or by traffic.
Measurement in road and railway tunnels
For control of tunnel ventilation
For detection of smoke propagation
Key Benefits
- Representative measurement across total tunnel width
- Very reliable measurement, compared with punctual measurement methods
- Accurate measurement even of very low flow velocities
- Long maintenance intervals of up to 5 years
- Low operating costs due to reliable operation and low maintenance
- High availability of devices and, therefore, of measurement data also
Specifications
Brand
Industry
- Other industries
Product Family
- FLOWSIC
Gas
Measured variables
- Flow velocity, Direction of flow, temperature
Measuring range
- Flow Velocity: 0 ... ± 20 m/s
Operating pressure range
- –100 hPa ... 100 hPa
Nominal pipe size
- FLOWSIC200 M, FLOWSIC200 H-M:3.5 m ... 22 m
- FLOWSIC200 H:3.5 m ... 35 m
Conformities
- RABT 2006
- ASTRA "Guideline - Ventilation of Road Tunnels" (2008)
- RVS 09.02.22
Outputs
- 1 output:
- 0/2/4 ... 20 mA, - 750 Ω
- Electrically isolated; additional outputs if using I/O modules (option)
Digital Outputs
- 5 relay outputs (change-over contacts), potential-free:
- - 48 V AC, 1 A
- Safety extra-low voltage; for status signals "operation/malfunction", "limit value", "warning", "maintenance" and "check cycle"
Digital communication
- RTU RS-485