Ultrasonic Flowmeter FLOWSIC IFL6XT
Brand: Endress+HauserUltrasonic Flowmeter FLOWSIC IFL6XT
Brand: Endress+Hauser
Xpert Specs at a Glance
Nominal pipe size:
3 ″ ... 56 ″
(DN 80 ... DN 1400), other nominal pipe sizes on request
(DN 80 ... DN 1400), other nominal pipe sizes on request
Measured variables:
Volumetric flow a. c., volume a. c., gas velocity, Speed of sound, optional volume correction via integrated, electronic volume corrector (EVC)
Measuring Medium:
Natural gas (with up to 30% hydrogen), air, natural gases containing increased levels of CO2, N2, H2S, O2, H2
Field of application
FLOWSIC600-XT is available in variants with 4, 4+1, 4+4, and 8 measurement paths. In addition to the OIML R 137 Class 1.0 requirements, FLOWSIC600-XT meets the requirements of Class 0.5 and AGA9 in their entirety. FLOWSIC600-XT contains i-diagnostics™ – an intelligent application diagnostics function – and PowerIn Technology™ for continuous measurement operation for up to three weeks in the event of a mains voltage failure. For the very best possible measurement accuracy and long-term stability.
Custody transfer measurement of natural gas
Custody transfer measurement of natural gas with up to 30% H2
Transport and storage of gas
Onshore and offshore applications
Key Benefits
- Low measurement uncertainty in every application
- Excellent measurement data reliability and availability
- The right ultrasonic gas flow measuring device for every application – without compromise
- Simple device integration – even in compact systems
- Quick and easy commissioning and checks
- Economical quantification of the H2 content in natural gas
Specifications
Brand
Industry
- Power & Energy
- Oil & Gas
Product Family
- FLOWSIC
Gas
Measured variables
- Volumetric flow a. c., volume a. c., gas velocity, Speed of sound, optional volume correction via integrated, electronic volume corrector (EVC)
Measuring Medium
- Natural gas (with up to 30% hydrogen), air, natural gases containing increased levels of CO2, N2, H2S, O2, H2
Repeatability
- ≤ 0.05 % of the measured value (typical)
Accuracy
- 4-path and 8-path version ≤ ± 0.5 % | (≤ ± 1%) Dry-calibrated
- 4-path and 8-path version ≤ ± 0.2 % | (≤ ± 0.5%) After flow calibration and alignment using constant factor. Without the calibration uncertainty of the test bench.
- 4-path and 8-path version ≤ ± 0.1 % | (≤ ± 0.2%) After flow calibration and alignment using polynomial or piecewise correction. Without the calibration uncertainty of the test bench.
Medium temperature range
- –46 °C ... +180 °C / -51 °F ... +356 °F
- On request:–194 °C ... +280 °C / –381 °F ... +536 °F
Operating pressure range
- 0 bar (g) ... 450 bar (g) 0 psi (g) ... 6527 psi (g)
Nominal pipe size
- 3 ″ ... 56 ″
- (DN 80 ... DN 1400), other nominal pipe sizes on request
Metrological approvals and certificates
- OIML R 137-1&2:2012 (class 0.5)
- OIML D 11:2013
- ISO 17089-1
- AGA-Report Nr. 9
- MID: 2014/32/EU
- PED: 2014/68/EU
- ASME: B16.5, B16.47 A/B
- ATEX: 2014/34/EU
- EMC: 2014/30/EU
- GOST 8.611-2013
- GOST 8.733-2011
- CPA: JJG1030-2007
- PCEC: GB 3836.1-2010, GB 3836.2-2010, GB 3836.4-2010, GB/T 3836.22-2017
Hazardous area approvals
- IECEx
- Ex db ia op is [ia Ga] IIA/IIC T4 Gb
- Ex db eb ia op is [ia Ga] IIA/IIC T4 Gb
- Ex ia op is IIA/IIC T4 Ga
- ATEX
- II 2 (1) G Ex db ia op is [ia Ga] IIA/IIC T4 Gb
- II 2 (1) G Ex db eb ia op is [ia Ga] IIA/IIC T4 Gb
- II 1G Ex ia op is IIA/IIC T4 Ga
- NEC/CEC (US/CA)
- Explosion-proof / non-incendive:
- CI I, Div. 1 Group D, T4 / Ex d ia [ia Ga] IIA T4 Gb / Cl I, Zone 1 AEx d ia op is [ia Ga] IIA T4 Gb
- CI I, Div. 1 Groups B, C, D, T4 / Ex d ia [ia Ga] IIC T4 Gb / Cl I, Zone 1 AEx d ia op is [ia Ga] IICT4 Gb
- Intrinsically safe:
- CI I, Div. 1 Group D T4 / Ex ia IIA T4 Ga / Cl I, Zone 0, AEx ia op is IIA T4 Ga
- CI I, Div. 1 Groups A, B, C, D, T4 / Ex ia IIC T4 Ga / Cl I, Zone 0, AEx ia op is IIC T4 Ga
Digital Outputs
- 4 outputs: 2 x status, 2 x pulse:
- ≤ 30 V, 50 mA
- Passive, electrically isolated, open collector or conforming to NAMUR (DIN EN 60947-5-6), fmax = 10 kHz(scalable)
Digital communication
- Modbus TCP