Specs at a Glance

Measuring Medium:
Natural gas, air, C2H4, steam, process gases (e. g. CO2 up to 100%, N2, O2, Cl2 etc.), gases like sour gas or bio gas with high H2S content
Measured variables:
Volumetric flow, a. c., volume a. c., gas velocity, sound velocity
Nominal pipe size:
2" ... 24"
(DN 50 ... DN 600)

Field of application

The FLOWSIC600 is an ultrasonic flowmeter that sets the standard in its market segment. The design shows that it is geared towards the harsh conditions of the industry. Thanks to its compact design with integrated cable routing, the measuring system is durable, fail-safe, low-maintenance, and exhibits long-term stability. The FLOWSIC600 has extensive diagnostic options that allow faults to be detected before the measurement is affected and offers process monitoring based on the speed of sound.

Process gases flow metering

Industry gas metering CO2, H2, Air, N2, O2, NH3, Ethylene, Helium, Argon

Internal allocation measurement

For gases with high H2S component such as sour gas or biogas

Key Benefits

  • Long-term stability, reliable measurement
  • Low maintenance due to intelligent self-diagnostics
  • Virtually immune to pressure regulator noise
  • Ultrasonic transducers can be exchanged under operating pressure
  • Wide application range

Specifications

Industry

  • Chemical
  • Power & Energy
  • Oil & Gas

Product Family

  • FLOWSIC

Gas

Measured variables

  • Volumetric flow, a. c., volume a. c., gas velocity, sound velocity

Measuring Medium

  • Natural gas, air, C2H4, steam, process gases (e. g. CO2 up to 100%, N2, O2, Cl2 etc.), gases like sour gas or bio gas with high H2S content

Repeatability

  • < 0.1 % of the measured value

Accuracy

  • 2-path version ≤ ± 1 %
  • 4-path version ≤ ± 0.5 %
  • Typical accuracy, see application specific data for detailed information

Medium temperature range

  • ATEX:
  • –40 °C ... +105 °C at T1, T2, T3;
  • –40 °C ... +91 °C at T4
  • Other Ex certifications: –40 °C ... +180 °C

Operating pressure range

  • 0 bar (g) ... 250 bar (g)
  • On request: Up to 450 bar (g)

Nominal pipe size

  • 2" ... 24"
  • (DN 50 ... DN 600)

Metrological approvals and certificates

  • ISO 17089-2
  • MTBF: 15.4 years

Hazardous area approvals

  • IECEx:
  • Gb/Ga Ex db eb ib [ia Ga] IIA T4
  • Gb/Ga Ex db eb ib [ia Ga] IIC T4
  • Ultrasonic transducers intrinsically safe
  • ATEX:
  • II 1/2 (1) G Ex ia/db eb ia [ia Ga] IIA/IIB/IIC T4...T1 Ga/Gb
  • III 1/2 (1) G Ex ia/db eb ia [ia Ga] IIC T6 Ga/Gb
  • NEC/CEC (US/CA):
  • Class I, Division 1, Groups B, C, D T4
  • Class I, Division 2, Groups A, B, C, D T4
  • Class I, Division 1, Group D T4
  • Class I, Division 2, Group D T4

Digital Outputs

  • 3 outputs:
  • 30 V, 10 mA
  • Passive, electrically isolated, Open Collector or according to NAMUR (EN 50227), fmax = 6 kHz
  • (scalable)

Digital communication

  • Modbus ASCII
  • Modbus RTU
  • HART

Documentation

show more