FLOWSIC IFL100
Brand: Endress+HauserFLOWSIC IFL100
Brand: Endress+Hauser
Xpert Specs at a Glance
Measuring range:
Gas Velocity: 0 ... ± 40 m/s
Measured variables:
Volumetric flow a. c., volumetric flow s. c., gas velocity, sound velocity, gas temperature
Field of application
FLOWSIC100 was designed for emission monitoring tasks. The "H" versions are suitable for stacks with large diameters and applications with high dust content. The ultrasonic transducers of the "PR" probe type are mounted with fixed path length on one sender/receiver unit (measuring probe). The "AC" versions have an innovative internal cooling and are suitable for gas temperatures up to 450 °C. The purged "Px" versions are used for gases with high concentrations of sticky or wet dust.
Emission monitoring in the chemical and hydrocarbon processing (HPI) industry
Emission measurement in the processing industry (cement, iron and steel, glass)
Key Benefits
- Reliable flow measurement for ducts with small up to very large diameters
- No purge air required for applications with gas temperatures up to 260 °C
- Minimum operating and maintenance costs
- Accurate measuring inputs under difficult measuring conditions
- Measurement without pressure loss, therefore no influences on the process
- User-friendly operation via SOPAS ET software
- Reliable function monitoring due to enhanced diagnosis
Specifications
Brand
Industry
- Power & Energy
- Oil & Gas
Product Family
- FLOWSIC
Gas
Measured variables
- Volumetric flow a. c., volumetric flow s. c., gas velocity, sound velocity, gas temperature
Measuring range
- Gas Velocity: 0 ... ± 40 m/s
Medium temperature range
- –40 °C ... +260 °C
Operating pressure range
- –100 hPa ... 100 hPa
Nominal pipe size
- 0,15 ... 13m
Conformities
- 2001/80/EC (13. BImSchV)
- 2000/76/EC (17. BImSchV)
- 27. BImSchV
- 30. BImSchV
- TA-Luft (Prevention of Air Pollution)
- EN 15267
- EN 14181
- EN 16911-2
- MCERTS
- GOST
Outputs
- 1 output:
- 0/2/4 ... 20 mA, + 750 Ω
- Electrically isolated, up to five outputs when add-on modules are used (option)
Digital Outputs
- 5 relay outputs (change-over contacts), potential-free:
- + 48 V, 1 A
- Safety extra-low voltage; for status signals "operation/malfunction", "limit value", "warning", "maintenance" and "check cycle"
Digital communication
- ASCII RS-485 (via optional interface module)
- RTU RS-485 (via optional interface module)
- TCP (via optional interface module)
- Profibus (Via optional interface module)