FLOWSIC IFL300

Brand: Endress+Hauser

FLOWSIC IFL300

Brand: Endress+Hauser

Eastern Controls, Endress+Hauser's exclusive USA representative in:
● DE ● MD ● NJ ●  Metro NY ● Eastern PA 

Xpert Xpert

Specs at a Glance

Measuring range:
Gas velocity 0.3 ... 60 m/s
Depending on the nominal size of the pipe
Measured variables:
Volumetric flow a. c., volume a. c., gas velocity, sound velocity

Field of application

The FLOWSIC300 ultrasonic flowmeter features a unique combination of high quality components, large measuring range, simple installation, and low installation costs. It can be used anywhere where custody approval is not required: For internal measurements in the natural gas grid and with process measurements in the petrochemical industry. FLOWSIC300 incorporates proven technology and components of the rugged custody transfer quality gas flowmeters for custody transfer.

Gas flow measurement in non custody transfer applications

Control measurements in the field of natural gas transfer and storage

Internal measurements for balancing purposes

Key Benefits

  • Simple installation into existing pipelines
  • Efficient solution, especially for pipe diameters over 12 inches, thanks to installation onto existing pipelines and without need for a meter body
  • Reduced acquisition costs – the sensor extraction tool can be used for multiple devices
  • Low maintenance, wear and no deterioration
  • Low operating costs thanks to automated diagnostics and condition-based maintenance
  • Suitable for installation in underground compartments via remote electronics and sensors with enclosure rating IP 68

Specifications

Industry

  • Power & Energy
  • Oil & Gas

Product Family

  • FLOWSIC

Gas

Measured variables

  • Volumetric flow a. c., volume a. c., gas velocity, sound velocity

Measuring range

  • Gas velocity 0.3 ... 60 m/s
  • Depending on the nominal size of the pipe

Max. Measurment error

  • Max. 1:130

Medium temperature range

  • –40 °C ... +180 °C

Operating pressure range

  • 10 bar (g) ... 100 bar (g)

Nominal pipe size

  • 4 ″ ... 56 ″

Hazardous area approvals

  • ATEX: II 1/2G Ex de iB [ia] IIC Ta
  • The ultrasonic transducers are intrinsically safe: "ia"

Outputs

  • 3 outputs:
  • Passive, electrically isolated, Open Collector or according to NAMUR (EN 50227), fmax = 6 kHz (scalable)

Digital Outputs

  • 5 relay outputs (change-over contacts), potential-free:
  • - 48 V AC, 1 A
  • Safety extra-low voltage; for status signals "operation/malfunction", "limit value", "warning", "maintenance" and "check cycle"

Digital communication

  • ASCII RS-485
  • RTU RS-485

Documentation

show more