FLOWSIC IFL6DR
Brand: Endress+HauserFLOWSIC IFL6DR
Brand: Endress+Hauser
Xpert Specs at a Glance
Measured variables:
Volumetric flow a. c., volume a. c., gas velocity, sound velocity
Nominal pipe size:
2" / 3" / 4"
Measuring Medium:
Natural gas, Associated gas , Raw Natural gas
Field of application
FLOWSIC600 DRU-S is a compact and innovative ultrasonic gas flowmeter for gas production. The gas meter is specifically designed for wellhead and gaslift applications. With a measuring range of more than 1:100, the FLOWSIC600 DRU-S covers flow ranges that previously required several orifice plates. Its special "wet gas robust" design ensures continuous measurement even under continuous high liquid loads. FLOWSIC600 DRU-S allows remote monitoring of measurement and diagnostic data.
Natural gas measurement in gas production
Associated gas measurement in oil production
Wellhead and gaslift measurement
Raw natural gas measurement at gas treatment plants (VRU, VRT, dehydration units, etc.)
Key Benefits
- Highly reliable – continuous gas measurement even in wet and dirty process conditions
- Low initial investment - accurate measurement without expensive flow calibration
- Elimination of scheduled maintenance with real-time remote diagnostics
- Advanced process monitoring capability with unique liquid detection
- Long life - wet gas resistant titanium ultrasonic sensors
Specifications
Brand
Industry
- Power & Energy
- Oil & Gas
Product Family
- FLOWSIC
Gas
Measured variables
- Volumetric flow a. c., volume a. c., gas velocity, sound velocity
Measuring Medium
- Natural gas, Associated gas , Raw Natural gas
Repeatability
- ± 0.2 % of the measured value
- (between Qt and Qmax depending on the installation requirements)
Accuracy
- Error limits Qt ... Qmax ± 2 %
Medium temperature range
- –40 °C ... +100 °C / –40 °F … 212 °F
Operating pressure range
- 0 bar(g) … 16 bar(g) / 0 psi(g) … 230 psi(g) for ANSI CL150
- 0 bar(g) … 100 bar(g) / 0 psi(g) … 1450 psi(g) for ANSI CL600
Nominal pipe size
- 2" / 3" / 4"
Hazardous area approvals
- IECEx:
- Gb/Ga Ex db eb ib [ia Ga] IIA T4
- Ultrasonic transducer, intrinsically safe
- ATEX:
- II 1/2 (1) G Ex ia/ db eb ia [ia Ga] IIA T4 …T1 Ga/Gb
- NEC/CEC (US/CA):
- Class I, Division 1, Group D T4
- Class I, Division 2, Group D T4
- Ultrasonic transducers intrinsically safe
Digital Outputs
- 2 DO and 1 FO:
- 30 V, 10 mA
- Passive, galvanically isolated, open collector, fmax = 6 kHz (scalable)
Digital communication
- RTU RS-485 (2x, for configuration, data output and diagnostics)
- ASCII RS-485 (2x, for configuration, data output and diagnostics)